# BypassValve Config type: `"BypassValve"` Source: `crates/components/src/bypass_valve.rs` (or valve module) --- ## EN ### Purpose & model Bypass leg valve with opening characteristic (linear / equal-percentage / custom). Parallel path around a component (compressor, HX, etc.). ``` ṁ = f(opening, ΔP, kv, characteristic) h_out ≈ h_in ``` ### Residuals Flow residual + energy (isenthalpic or low Δh). ### Ports `inlet` / `outlet`. ### Actuator `opening` ∈ [0, 1] — free when under control. ### JSON (main) | Key | Meaning | Default | |-----|---------|---------| | `opening` | 0–1 | 0–1 | | `kv` | capacity | – | | characteristic | linear / … | linear | --- ## FR ### But **Vanne de by-pass** sur une branche parallèle. ### Actionneur Ouverture 0–1. ### JSON Voir EN.