Anchor & HeatSource (inline BOLT-style nodes)

Config types: "Anchor" / "RefrigerantNode", "HeatSource"
Source: anchor / heat source modules in components


EN

Anchor (Refrigerant.Node)

Inline probe or spec on a refrigerant edge:

Mode Behaviour DoF
Probe (no key) measures P/T/SH/SC — DoF-neutral 0 equations
Spec imposes one of superheat_k, quality, t_c/t_k, p_bar +1 equation

When imposing, free something elsewhere (emergent pressure, free actuator, free boundary).

HeatSource (Heat.Source)

Injects q_w (or q_kw) into the stream energy balance:

ṁ · (h_out  h_in) = Q_heat

Negative Q extracts heat. Can be linked as cold_component of a thermal coupling (motor cooling pattern).

Ports

Inline on a single branch (inlet/outlet pass-through).

Calibration

None required for probe mode.

JSON (main)

Key Component Meaning
superheat_k / quality / t_c / p_bar Anchor one optional FIX
q_w / q_kw HeatSource heat injection

FR

Anchor

Sonde (0 DoF) ou une spécification (+1 équation) : SH, x, T ou P.

HeatSource

Injection de chaleur Q dans le bilan dénergie du fluide.

DoF

Imposer une spec Anchor ⇒ libérer ailleurs.