Ship the Next.js cycle editor with CAD chrome, technical HX symbols, Fixed/Free boundary guidance, and secondary water/air pressure drop support in the solver stack. Co-authored-by: Cursor <cursoragent@cursor.com>
1.3 KiB
1.3 KiB
Anchor & HeatSource (inline BOLT-style nodes)
Config types: "Anchor" / "RefrigerantNode", "HeatSource"
Source: anchor / heat source modules in components
EN
Anchor (Refrigerant.Node)
Inline probe or spec on a refrigerant edge:
| Mode | Behaviour | DoF |
|---|---|---|
| Probe (no key) | measures P/T/SH/SC — DoF-neutral | 0 equations |
| Spec | imposes one of superheat_k, quality, t_c/t_k, p_bar |
+1 equation |
When imposing, free something elsewhere (emergent pressure, free actuator, free boundary).
HeatSource (Heat.Source)
Injects q_w (or q_kw) into the stream energy balance:
ṁ · (h_out − h_in) = Q_heat
Negative Q extracts heat. Can be linked as cold_component of a thermal coupling (motor cooling pattern).
Ports
Inline on a single branch (inlet/outlet pass-through).
Calibration
None required for probe mode.
JSON (main)
| Key | Component | Meaning |
|---|---|---|
superheat_k / quality / t_c / p_bar |
Anchor | one optional FIX |
q_w / q_kw |
HeatSource | heat injection |
FR
Anchor
Sonde (0 DoF) ou une spécification (+1 équation) : SH, x, T ou P.
HeatSource
Injection de chaleur Q dans le bilan d’énergie du fluide.
DoF
Imposer une spec Anchor ⇒ libérer ailleurs.