Entropyk CLI

Interface en ligne de commande pour lancer, valider et noter des simulations thermodynamiques à partir de fichiers JSON.

Binaire : entropyk-cli · Crate : crates/cli · Exemples : crates/cli/examples/

Le README racine (../../README.md) décrit larchitecture globale, les composants et le solveur. Ce document se concentre sur lusage CLI.


Installation

cargo build --release -p entropyk-cli

# Binaire
./target/release/entropyk-cli --help          # Linux / macOS
.\target\release\entropyk-cli.exe --help      # Windows

Ou sans installer :

cargo run -p entropyk-cli -- <sous-commande> ...

Flags globaux : -v / --verbose, -q / --quiet.


Sous-commandes

Commande Rôle
run Une simulation depuis un JSON
batch Un dossier de configs, en parallèle
validate Vérifie la config (parse / topologie)
qualify Qualification HX (régime frigorigène fixe)
rate IPLV (AHRI 550/590) / ESEER
scop SCOP EN 14825 (bins chauffage)
seer SEER EN 14825 (bins froid)
schema Émet le JSON Schema du Model IR

Exemples

# Simulation unique
cargo run -p entropyk-cli -- run \
  --config crates/cli/examples/chiller_aircooled_r134a.json \
  --output result.json

# Validation
cargo run -p entropyk-cli -- validate --config mon_cycle.json

# Batch (4 workers)
cargo run -p entropyk-cli -- batch -d ./scenarios/ -p 4 -O results.json

# Rating IPLV
cargo run -p entropyk-cli -- rate -c crates/cli/examples/rate_chiller_iplv_ahri.json

# SCOP
cargo run -p entropyk-cli -- scop -c crates/cli/examples/scop_heatpump_r134a.json

# Schema
cargo run -p entropyk-cli -- schema -o model-ir.schema.json

Pipeline de run

  1. Parse ScenarioConfig (fluide, circuits, edges, controls, solver)
  2. Pour chaque composant : create_component (crates/cli/src/run.rs)
  3. Câblage des arêtes nom:portnom:port
  4. finalize() + porte DoF (système carré obligatoire)
  5. Seed initial (frontières + staging HP/BP si emergent_pressure)
  6. Solve : newton | picard | fallback
  7. Sortie JSON : états, performances, dof, erreurs / failure_diagnostics

Format de configuration

Structure racine

{
  "name": "Mon chiller",
  "description": "optionnel",
  "fluid": "R134a",
  "fluid_backend": "CoolProp",
  "circuits": [ { "id": 0, "components": [], "edges": [] } ],
  "controls": [],
  "thermal_couplings": [],
  "solver": {
    "strategy": "newton",
    "max_iterations": 300,
    "tolerance": 1e-6
  }
}
Champ Description
fluid Frigorigène principal du circuit (ex. R134a, R410A)
fluid_backend CoolProp (défaut sérieux), Tabular, etc.
circuits[] Un ou plusieurs circuits (id 0…n)
components[] Objets avec type, name, + paramètres
edges[] { "from": "comp:outlet", "to": "cond:inlet" }
controls[] Boucles inverse / SaturatedController (optionnel)
solver.strategy newton (défaut), picard, fallback

Exemple moderne (chiller air, 4 ports)

Voir examples/chiller_aircooled_r134a.json — pattern recommandé :

  • IsentropicCompressor + emergent_pressure
  • Condenser / Evaporator avec secondaires AirSource/BrineSource → HX → sinks
  • IsenthalpicExpansionValve isenthalpique (sans orifice sauf besoin)
  • Sources : Fixed T + Fixed ṁ + Free P ; sinks : Fixed P
cargo run -p entropyk-cli -- run \
  -c crates/cli/examples/chiller_aircooled_r134a.json

Types de composants CLI

Chaînes type reconnues par create_component (liste non exhaustive — voir le match dans src/run.rs).

Compresseurs

Type Paramètres utiles
IsentropicCompressor displacement_m3, speed_hz, volumetric_efficiency, isentropic_efficiency, emergent_pressure
Compressor Cartes AHRI 540 (m1m10) ou SST/SDT
ScrewEconomizerCompressor / ScrewCompressor Courbes SST/SDT, VFD, slide valve
CentrifugalCompressor diameter_m, speed_rpm, γ, R

Détente

Type Paramètres utiles Attention
IsenthalpicExpansionValve / EXV emergent_pressure, t_evap_k Sans orifice_kv, opening est ignoré
ExpansionValve opening, flow_model, beta_m2
CapillaryTube diameter_m, length_m, n_segments
ReversingValve / FourWayValve mode, pressure_drop_pa
BypassValve opening, cv

EXV orifice (débit physique) :

{
  "type": "IsenthalpicExpansionValve",
  "name": "exv",
  "emergent_pressure": true,
  "orifice_kv": 2.0e-6,
  "opening": 0.6,
  "fix_opening": true
}

Loi : ṁ = Kv · opening · √(2 · ρ · max(ΔP, 0)).
Avec orifice Fixed, le CLI met le compresseur en ṁ métré. Voir examples/chiller_r134a_exv_orifice.json.

Échangeurs

Type Paramètres utiles
Condenser / Evaporator ua, emergent_pressure, subcooling_k / SH, secondary_fluid, ΔP secondaire
FloodedEvaporator ua, quality_control
HeatExchanger ua, hot_fluid_id, cold_fluid_id (4 ports)
BphxEvaporator / BphxCondenser Géométrie plaques + corrélations
AirCooledCondenser, FinCoilCondenser, MchxCondenserCoil Bobines air / MCHX
FreeCoolingExchanger Free-cooling eau

Secondaire 4 ports :

BrineSource/AirSource → HX:secondary_inlet → HX:secondary_outlet → BrineSink/AirSink

ΔP secondaire de rating (optionnel) :

"secondary_rated_pressure_drop_pa": 40000,
"secondary_rated_m_flow_kg_s": 0.5

Tuyauterie / machines tournantes

Type Notes
Pipe / RefrigerantPipe / WaterPipe / AirDuct length_m, diameter_m ; pressure_drop_pa = 0Darcy L/D ; > 0 → ΔP imposé
Pump, Fan Courbes + affinity laws
FlowSplitter, FlowMerger, Drum Jonctions / séparateur

Frontières

Type Flags Fixed/Free
BrineSource / BrineSink fix_pressure, fix_temperature, fix_mass_flow
AirSource / AirSink idem (+ psychrométrie t_dry_c, rh)
RefrigerantSource / RefrigerantSink P, qualité / h, ṁ

Défaut recommandé (Modelica MassFlowSource_T) : source Fixed T + Fixed ṁ + Free P ; sink Fixed P.

Voir docs/modelica-boundary-proof.md.

Divers

ThermalLoad, HeatSource, Anchor / RefrigerantNode, Placeholder.


Contrôles (régulation / calibration)

"controls": [
  {
    "type": "SaturatedController",
    "id": "sh_loop",
    "measure": { "component": "evap", "output": "superheat" },
    "actuator": {
      "component": "exv",
      "factor": "opening",
      "initial": 0.5,
      "min": 0.1,
      "max": 1.0
    },
    "target": 5.0
  }
]

Chaque boucle ajoute des inconnues dactionneur + résidus de tracking. Le système doit rester DoF-carré (mesure FIX ↔ actionneur FREE).


Stratégies solveur

Valeur Comportement
newton NewtonRaphson (défaut). Armijo activé si contrôles, orifice EXV, ou Free-P sur BrineSource.
picard Substitution successive amortie (ω ≈ 0,5)
fallback Newton → Picard si divergence → retour Newton si résidu bas
"solver": {
  "strategy": "newton",
  "max_iterations": 300,
  "tolerance": 1e-6
}

Si le résidu décroît lentement (Jacobien partiellement numérique sur certains HX), augmenter max_iterations (ex. 1000).


Sortie et codes de sortie

Sortie typique JSON (--output) :

  • status : converged / Error / …
  • iterations, state (arêtes : ṁ, P, h…)
  • performance (puissances, COP…)
  • dof (équations vs inconnues)
  • error, failure_diagnostics si échec après itérations
Code Signification
0 Succès
1 Erreur de simulation / non-convergence
2 Erreur de configuration
3 Erreur I/O

Exemples fournis (examples/)

Fichier Intérêt
chiller_aircooled_r134a.json Chiller air 4 ports, emergent
chiller_watercooled_r410a.json Chiller eau R410A
chiller_flooded_4port_watercooled.json FloodedEvaporator
chiller_r134a_emergent_pressure.json Pressions émergentes
chiller_r134a_exv_orifice.json EXV orifice (opening physique)
chiller_r134a_superheat_control.json Boucle SH
heatpump_airsource_r410a.json PAC air
heatpump_r410a_reversing_valve.json Vanne 4 voies
hx_air_water_4port.json HX isolé
bphx_evaporator_condenser.json Plaques brasées
capillary_tube_r134a.json Capillaire
rate_chiller_iplv_ahri.json Rating IPLV
scop_heatpump_r134a.json SCOP

Pièges fréquents

  1. EXV opening sans effet → il manque orifice_kv (sinon isenthalpique seul ; ṁ = compresseur).
  2. DoF under-constrained → source Free P sans fermeture P sur le HX/pipe ; ou oubli de brancher le secondaire 4 ports.
  3. DoF over-constrained → Fixed ṁ et Fixed P sur la même frontière ; ou double Fixed-P sans ΔP.
  4. Pipe isobare → avec lancien défaut mental « ΔP=0 = rien » : aujourdhui pressure_drop_pa = 0 déclenche Darcy depuis L/D.
  5. Exemples obsolètes cités dans danciennes docs (chiller_r410a_full.json, etc.) → utiliser la table ci-dessus.

Voir aussi