Boundaries — Sources & Sinks / Frontières

Config types: RefrigerantSource, RefrigerantSink, BrineSource, BrineSink, AirSource, AirSink
Sources: refrigerant_boundary.rs, brine_boundary.rs, air_boundary.rs


EN

Boundary components fix Dirichlet conditions on one edge.
Source = one outlet; Sink = one inlet. These are the natural place to FIX machine inputs (T, P, ṁ).

RefrigerantSource / RefrigerantSink

Source: P = P_set ; h = h(P, x)           n ≈ 2
Sink:   P = P_back ; optional h if x set    n ≈ 12
Key Meaning Default
fluid refrigerant primary
p_set_bar / p_back_bar pressure ~10 bar typical
quality vapor quality 1.0 source

BrineSource / BrineSink (water / glycol)

Source: P, h(T), optional ṁ_set     n = 2 or 3
Sink:   P_back, optional T/h, ṁ     n = 13
Key Meaning Default
fluid Water / MEG / … Water
p_set_bar / p_back_bar pressure 2 bar
t_set_c temperature 12 °C (source)
concentration glycol mass % 0
m_flow_kg_s imposed loop flow (BOLT Vd_fixed) optional

Do not combine m_flow_kg_s with another flow imposition on the same branch (pump curve + fixed ṁ → over-constrained).

AirSource / AirSink

Psychrometric state (MagnusTetens style humidity + moist air enthalpy):

h ≈ 1006·T_c + W·(2.501e6 + 1860·T_c)
Source: fix P, h(T, RH)     n = 2
Key Meaning Default
t_dry_c / t_set_c dry-bulb
rh relative humidity
p_set_bar pressure ~1 bar
m_flow_kg_s optional mass flow

System wiring for HX secondary

BrineSource.outlet → HX.secondary_inlet
HX.secondary_outlet → BrineSink.inlet

Without live wiring, HX may still run in rating mode with scalar secondary_* on the HX itself.

Calibration

Boundaries generally have no Z-factors. They are pure Fixed inputs / back-pressure.


FR

Rôle

Imposent les conditions aux limites (P, T, ṁ). Cest là quon fixe les entrées machine.

Eau (Brine)

Source : P, T, ṁ optionnel. Sink : contre-pression (T sortie souvent libre = émergente).

Air

État psychrométrique (T sèche, HR → h).

Câblage HX

Source → secondary_in → secondary_out → Sink pour le mode système.

JSON

Voir tableaux EN.