Files
Entropyk/apps/web/public/docs/components/bypass-valve.md
sepehr 3358b74342 Add diagram workbench UI with Modelica DoF coaching and ISO glyphs.
Ship the Next.js cycle editor with CAD chrome, technical HX symbols, Fixed/Free boundary guidance, and secondary water/air pressure drop support in the solver stack.

Co-authored-by: Cursor <cursoragent@cursor.com>
2026-07-17 22:46:46 +02:00

812 B
Raw Blame History

BypassValve

Config type: "BypassValve"
Source: crates/components/src/bypass_valve.rs (or valve module)


EN

Purpose & model

Bypass leg valve with opening characteristic (linear / equal-percentage / custom). Parallel path around a component (compressor, HX, etc.).

ṁ = f(opening, ΔP, kv, characteristic)
h_out ≈ h_in

Residuals

Flow residual + energy (isenthalpic or low Δh).

Ports

inlet / outlet.

Actuator

opening ∈ [0, 1] — free when under control.

JSON (main)

Key Meaning Default
opening 01 01
kv capacity
characteristic linear / … linear

FR

But

Vanne de by-pass sur une branche parallèle.

Actionneur

Ouverture 01.

JSON

Voir EN.