Ship the Next.js cycle editor with CAD chrome, technical HX symbols, Fixed/Free boundary guidance, and secondary water/air pressure drop support in the solver stack. Co-authored-by: Cursor <cursoragent@cursor.com>
974 B
974 B
Fan
Config type: "Fan"
Source: crates/components/src/fan.rs
EN
Purpose & model
Air-moving machine with performance curves (pressure rise / power vs flow and speed). Typestate ports: disconnected → connected.
Affinity laws may scale curves with rotational speed.
Residuals & n_equations()
Curve residuals linking ΔP, ṁ (or volume flow), and speed; energy/power residual when power is modeled. See n_equations() in source (typically small fixed count for the fan node).
Ports
inlet / outlet on the air branch.
Calibration
Curve multipliers / Z-style factors when exposed via calib API (default unity).
JSON (main)
| Key | Meaning | Default |
|---|---|---|
| curve data / preset | performance map | required |
speed / ratio |
operating speed | 1.0 full |
FR
But & modèle
Ventilateur sur courbes ΔP / débit / vitesse.
Ports
Entrée / sortie air.
JSON
Voir EN.