Pipe

Config type: "Pipe"
Source: crates/components/src/pipe.rs


EN

Purpose & model

Fluid duct with friction pressure drop (Darcy/Colebrook-style or equivalent implementation) and near-isenthalpic or adiabatic energy transport:

ΔP = f(L, D, ε, Re, ṁ, ρ)
h_out ≈ h_in   (or with small heat loss if modeled)

Residuals & n_equations()

Pressure-drop residual + energy residual (typically 2 on a series branch).

Ports

inlet / outlet.

Calibration

z_dp (or equivalent) scales ΔP when exposed via calib — default 1.0.

JSON (main)

Key Meaning Default
length_m length required
diameter_m inner diameter required
roughness_m roughness small metal default
fluid water / refrigerant path from circuit

FR

But & modèle

Conduite avec pertes de charge et transport denthalpie.

Calibration

Facteur de perte de charge (défaut 1).

JSON