Ship the Next.js cycle editor with CAD chrome, technical HX symbols, Fixed/Free boundary guidance, and secondary water/air pressure drop support in the solver stack. Co-authored-by: Cursor <cursoragent@cursor.com>
997 B
997 B
Pump
Config type: "Pump"
Source: crates/components/src/pump.rs
EN
Purpose & model
Liquid pump with head/power curves vs volume flow and speed. Typestate connect pattern like Fan.
ΔP = ρ · g · H(Q, N)
Ẇ = f_power(Q, N)
Residuals & n_equations()
Head residual + energy/power residual as implemented; see source n_equations().
Ports
inlet / outlet on liquid (brine/water) branch.
DoF warning
Do not impose m_flow_kg_s on a BrineSource and a pump curve on the same branch without freeing one — over-constrained loop.
Calibration
Curve scale factors when exposed (default 1.0).
JSON (main)
| Key | Meaning | Default |
|---|---|---|
| curves / preset | H–Q map | required |
| speed | operating speed | – |
FR
But & modèle
Pompe liquide sur courbes H–Q.
Attention DoF
Ne pas imposer ṁ Source et courbe pompe sur la même branche.
Ports / JSON
Voir EN.