# BypassValve
|
||
|
||
Config type: `"BypassValve"`
|
||
Source: `crates/components/src/bypass_valve.rs` (or valve module)
|
||
|
||
---
|
||
|
||
## EN
|
||
|
||
### Purpose & model
|
||
|
||
Bypass leg valve with opening characteristic (linear / equal-percentage / custom). Parallel path around a component (compressor, HX, etc.).
|
||
|
||
```
|
||
ṁ = f(opening, ΔP, kv, characteristic)
|
||
h_out ≈ h_in
|
||
```
|
||
|
||
### Residuals
|
||
|
||
Flow residual + energy (isenthalpic or low Δh).
|
||
|
||
### Ports
|
||
|
||
`inlet` / `outlet`.
|
||
|
||
### Actuator
|
||
|
||
`opening` ∈ [0, 1] — free when under control.
|
||
|
||
### JSON (main)
|
||
|
||
| Key | Meaning | Default |
|
||
|-----|---------|---------|
|
||
| `opening` | 0–1 | 0–1 |
|
||
| `kv` | capacity | – |
|
||
| characteristic | linear / … | linear |
|
||
|
||
---
|
||
|
||
## FR
|
||
|
||
### But
|
||
|
||
**Vanne de by-pass** sur une branche parallèle.
|
||
|
||
### Actionneur
|
||
|
||
Ouverture 0–1.
|
||
|
||
### JSON
|
||
|
||
Voir EN.
|