# HeatExchanger (generic)
Config type: `"HeatExchanger"`
Source: `crates/components/src/heat_exchanger/exchanger.rs` + ε-NTU / LMTD models
---
## EN
### Purpose & model
Generic two-stream HX with selectable model:
- **ε-NTU** effectiveness
- **LMTD** / counterflow forms
Ports: hot_in/out, cold_in/out (Modelica-style 4-port).
```
NTU = UA / C_min
ε = f(NTU, C_r, flow arrangement)
Q = ε · C_min · (T_hot,in T_cold,in)
```
**Requires live four-port edge state** for residual evaluation on the generic path — inlet-only scalar BCs do not invent outlet states.
### Residuals & `n_equations()`
Inner model residual count (often 23 per side balance depending on configuration).
### Ports
| Port | Role |
|------|------|
| `hot_inlet` / `hot_outlet` | hot stream |
| `cold_inlet` / `cold_outlet` | cold stream |
### Calibration
`z_ua` on UA (default 1.0).
### When not to use
For refrigeration condensers/evaporators prefer specialized `Condenser` / `Evaporator` / `FloodedEvaporator` / BPHX which know phase-change ε-NTU and secondary dual modes.
---
## FR
### But
Échangeur **générique** 4 ports (ε-NTU / LMTD).
### Attention
Exige un état **4 ports live**. Pour frigo, préférer Condenser / Evaporator / Flooded / BPHX.
### Calibration
Z_UA = 1 par défaut.