Drum (separator / recirculation drum)

Config type: "Drum"
Source: crates/components/src/drum.rs


EN

Purpose & model

Liquid/vapor separator used in flooded recirculation architectures. Splits a two-phase feed into liquid and vapor outlets; may accept an evaporator return.

Thermodynamics: equilibrium separation at drum pressure (quality split toward x≈0 liquid / x≈1 vapor legs), mass and energy balances across ports.

Residuals & n_equations()

Multi-port balance residuals (mass + energy + pressure consistency). Exact count depends on active ports and edge wiring; treat as a multi-equation node — see unit tests and n_equations() in source.

Ports (4-port naming)

Port Role
feed_inlet two-phase feed
evaporator_return return from flooded evaporator
liquid_outlet liquid to pump / recirculation
vapor_outlet vapor to compressor suction

Calibration

No primary Z-factor set; geometry/level control may be added in specialized builds.

JSON (main)

Key Meaning Default
fluid / refrigerant working fluid primary
level / volume options if exposed

System note

A flooded plate topology is often Drum + recirculation + DX exchanger — not a mode of BPHX alone. Shell-and-tube flooded use FloodedEvaporator.


FR

But & modèle

Ballon séparateur liquide/vapeur pour architectures noyées / recirculation.

Ports

Alimentation, retour évap, sortie liquide, sortie vapeur.

DoF

Nœud multi-équations ; équilibrer avec le reste du circuit.

JSON