ReversingValve / FourWayValve

Config types: "ReversingValve", "FourWayValve"
Source: reversing valve module


EN

Purpose & model

4-way reversing valve for heat-pump mode swap (heating ↔ cooling). Routes compressor discharge/suction between indoor and outdoor exchangers according to mode (or boolean heat/cool).

Ideal model: port permutation with negligible ΔP/Δh; real models may add leakage or pressure drop.

Residuals

Port coupling residuals matching the selected flow graph for the active mode.

Ports

Four refrigerant ports (naming depends on implementation: e.g. compressor discharge/suction, indoor, outdoor).

JSON (main)

Key Meaning Default
mode / reversing_mode heat / cool

Calibration

Usually none; treat as topology switch.


FR

But

Vanne 4 voies pour inverser le cycle PAC.

JSON

Mode chaud / froid. Voir EN.