# ReversingValve / FourWayValve
Config types: `"ReversingValve"`, `"FourWayValve"`
Source: reversing valve module
---
## EN
### Purpose & model
4-way reversing valve for heat-pump mode swap (heating ↔ cooling). Routes compressor discharge/suction between indoor and outdoor exchangers according to `mode` (or boolean heat/cool).
Ideal model: port permutation with negligible ΔP/Δh; real models may add leakage or pressure drop.
### Residuals
Port coupling residuals matching the selected flow graph for the active mode.
### Ports
Four refrigerant ports (naming depends on implementation: e.g. compressor discharge/suction, indoor, outdoor).
### JSON (main)
| Key | Meaning | Default |
|-----|---------|---------|
| `mode` / `reversing_mode` | heat / cool | |
### Calibration
Usually none; treat as topology switch.
---
## FR
### But
**Vanne 4 voies** pour inverser le cycle PAC.
### JSON
Mode chaud / froid. Voir EN.